Product details
Description
Description
General
● Applications: Automatic transfer switch Ideal for industries, commercial spaces, and critical infrastructure that require continuous power.
● Functionality: Automatically switches to backup power when the main supply fails, ensuring minimal service interruption.
● Efficiency: Designed to improve operational reliability by reducing downtime during power disruptions.
ATS Key Features
Seamless Power Transition
The YCQR-63 Automatic Transfer Switch ensures reliable, uninterrupted power by quickly switching between the main and backup power supplies.
● Fast Switching: The ATS switches between power sources in less than 50 milliseconds to minimize downtime.
● Automatic Operation: It automatically detects when the main power fails and shifts to backup power without manual intervention.
● Dual-Station Design: It features a two-station configuration, commonly used for main (A) and backup (B) power supplies.
Automatic Transfer SwitchSpecification
● Rated Current: 6A-63A
● Frequency: 50-60Hz AC systems
● Switching Speed: < 50 milliseconds
● Poles: 2 Poles
● Power Supply Types: Supports both main (A) and backup (B) power supplies
● CNC Electric

Working Conditions
Temperature:
- The temperature range of the operating environment is -5°C to +40°C, and the average temperature within 24 hours shall be lower than +35°C, and the temperature range of the storage environment is -25°C to +55°C, which can be reached +70°C in a short time (within 24 hours).
- The altitude of the installation site should be lower than 2000m.
- The relative temperature at the installation site shall not exceed 50% when the ambient air temperature is +40°C. Higher relative humidity is possible at lower temperatures. For example: when the average minimum temperature is low, higher humidity is acceptable.
· The temperature of the wettest month is +20°C, the monthly average maximum relative humidity of that month can reach 90%. Appropriate measures should be taken to prevent condensation due to temperature changes.
Pollution:
· Pollution level 3 (conductive pollution, or dry non-conductive pollution becomes conductive due to condensation). ATS can be installed vertically or horizontally in the cabinet. If there are special installation requirements, contact us. The protection grade of the ATS case is IP30.
Overvoltage category
Main circuit category III; control and auxiliary circuit category II.
Specifications
Specifications
|
Technical Data |
YCQR-63 |
|
Rated Current of Shell Frame Grade |
63 |
|
Rated Operating Current Ie(A) |
6A/10A/16A/20A/25A/32A/40A/50A/63A |
|
Rated Insulation Voltage Ui |
690V |
|
Rated Impulse Withstand Voltage Uimp |
8kV |
|
Rated Working Voltage Ue |
AC220V/AC110V |
|
Rated Frequency |
50/60Hz |
|
Class |
PC class: can be switched on and loaded without generating short-circuit current |
|
Pole Number |
2Pole |
|
Rated Short-Circuit Current Iq |
50kA |
|
Rated Short-Circuit Protection Device |
RT16-06-63A |
|
Rated Impulse Withstand Voltage |
8kV |
|
Control Circuit |
Rated control voltage Us: AC220V, SOHz Normal working conditions: 85%Us-110%Us |
|
Auxiliary Circuit |
AC220V/110V SO Hz le=SA |
|
Contactor Change-Over Time |
<50ms |
|
Operation Change-Over Time |
<50ms |
|
Return Change-Over Time |
<50ms |
|
Power Off Time |
<50ms |
|
Rated Change-Over Operation Time |
<50ms |
|
Mechanical Life |
≥8000 times |
|
Electrical Life |
≥1500 times |
|
Usage Category |
AC-31B |